Multiparameter Patient Monitor BW3C
Model | BW3C (15.1-inch TFT LCD) |
Min order | 1 |
Supply ability | 20000 pcs per year |
Payment | T/T, Western Union, MoneyGram, PayPal, L/C |
Port | Shenzhen, Hongkong, Guangzhou, Shanghai, Beijing, etc |
Certification | ISO13485 |
Delivery | 3-5 days after payment received |
Packaging | Standard carton box |
This multiparameter patient monitor, designed with 15.1-inch TFT LCD display, standard parameters including ECG, SPO2, NIBP (non-invasive blood pressure), Temperature, Pulse Rate, Optional parts including EtCO2, IBP (invasive blood pressure) and recorder, AG gas, CO (Cardiac Output) etc.
It's been widely used in hospitals and clinics during the combat against covid-19 virus (coronavirus) worldwide currently
Features
* 15.1" color TFT LCD display
* Attractive streamline outline design, portable, compact and lightweight
* Operation menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, German etc
* Big Font Display
* ST segment Analysis and Apnea Alarm function
* Drug Dose Calculation and OXCRG Software
* 72-hour tabular and graphic trends and data storage
* High energy Li-ion battery for short-term transport and temporary power-down
* Networking Capability. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
* Linux Operation System
* External display(VGA interface) and external printer connectible to record tabular and graphic trend
* Dynamic Monitoring of blood pressure
* Intelligent audio and visual alarm
* Application: Adult, Pediatric and Neonate
* Pacemaker detection and Arrhythmia Analysis( Optional)
Technical Specs:
ECG
Input: 5 lead ECG cable
Lead section: lead 1st, 2nd, 3rd, / aVR, aVL, aVF/ V
Gain (mm/mV): 1/4 1/2 1 2 4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor mode 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed (mm/sec): 12.5, 25, 50
Heart rate range: 20-254 BPM
ST segment deviation analysis: -0.8-+0.8mV
Protection: Against electrosurgical interference and defibrillation
NIBP
Method: Automatic Oscillometric
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Scale: mmHg/Kpa
Operating Mode: Manual/Auto/STAT
Over pressure Protection: Yes
SPO2
Measurement range: 0 - 100 %
Pulse Rate range: 30- 254BPM
Accuracy: up to 2 %
Probe: For Neonate, pediatric, and adult
Temperature
Channel: Two Channels
Measurement range: 29- 45 degree
Accuracy: up to 0.1 degree
Scale: Celsius/Fahrenheit
RESP.
Method: Impedance
Measurement range: 0 - 120 BPM
Lead Connection: RA & LL or RA & RA
Power requirements
Input: 98 to 260 V AC, 50/60Hz
Consumption: less than 80VA
Safety standards: GB9706.1 IEC 60601-1 UL 544
EtCO2( Optional)
Method: Side Stream
Measurement range: 0 % - 10.0 % in CO2 and et CO2)
Display: Waveform, Respiration Rate, EtCO2, FiCO2
Scale: mmHg/Kpa
2-IBP ( Optional)
Channel: 2 Channels
Parameter: SYS/DIA/MAP/Pulse Rate
Scale: mmHg/kPa
Recorder (Optional)
Type: Built-in Thermal Recorder
Print Mode: Waveform and/or Text
It's been widely used in hospitals and clinics during the combat against covid-19 virus (coronavirus) worldwide currently
Features
* 15.1" color TFT LCD display
* Attractive streamline outline design, portable, compact and lightweight
* Operation menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, German etc
* Big Font Display
* ST segment Analysis and Apnea Alarm function
* Drug Dose Calculation and OXCRG Software
* 72-hour tabular and graphic trends and data storage
* High energy Li-ion battery for short-term transport and temporary power-down
* Networking Capability. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
* Linux Operation System
* External display(VGA interface) and external printer connectible to record tabular and graphic trend
* Dynamic Monitoring of blood pressure
* Intelligent audio and visual alarm
* Application: Adult, Pediatric and Neonate
* Pacemaker detection and Arrhythmia Analysis( Optional)
Technical Specs:
ECG
Input: 5 lead ECG cable
Lead section: lead 1st, 2nd, 3rd, / aVR, aVL, aVF/ V
Gain (mm/mV): 1/4 1/2 1 2 4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor mode 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed (mm/sec): 12.5, 25, 50
Heart rate range: 20-254 BPM
ST segment deviation analysis: -0.8-+0.8mV
Protection: Against electrosurgical interference and defibrillation
NIBP
Method: Automatic Oscillometric
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Scale: mmHg/Kpa
Operating Mode: Manual/Auto/STAT
Over pressure Protection: Yes
SPO2
Measurement range: 0 - 100 %
Pulse Rate range: 30- 254BPM
Accuracy: up to 2 %
Probe: For Neonate, pediatric, and adult
Temperature
Channel: Two Channels
Measurement range: 29- 45 degree
Accuracy: up to 0.1 degree
Scale: Celsius/Fahrenheit
RESP.
Method: Impedance
Measurement range: 0 - 120 BPM
Lead Connection: RA & LL or RA & RA
Power requirements
Input: 98 to 260 V AC, 50/60Hz
Consumption: less than 80VA
Safety standards: GB9706.1 IEC 60601-1 UL 544
EtCO2( Optional)
Method: Side Stream
Measurement range: 0 % - 10.0 % in CO2 and et CO2)
Display: Waveform, Respiration Rate, EtCO2, FiCO2
Scale: mmHg/Kpa
2-IBP ( Optional)
Channel: 2 Channels
Parameter: SYS/DIA/MAP/Pulse Rate
Scale: mmHg/kPa
Recorder (Optional)
Type: Built-in Thermal Recorder
Print Mode: Waveform and/or Text